Conductivity transmitter
with high accuracy
- Compatible with the 3-wire conductivity sensors LMN-1-3L
- 2 variants with adjustable measuring range 10nS…200mS or 10mS…1000mS
- highest precision at an attractive price
- automatic temperature compensation
- second current output for temperature
- galvanic isolation
- For wall mounting or DIN rail
- Made in Germany
ab €256.00 net
Function
The new generation of MW22 and MW22-1000 transmitters for measuring electrical conductivity offers the highest precision at a very attractive price. The MW22 has a resolution of 0.1 nS in the recommended measuring range from 10nS to 50mS.
With both transmitter types, the sensor is connected via 3 wires, so the cable length no longer affects measuring accuracy. The NTC sensor built into the conductivity sensor is used for temperature compensation of the conductivity and for measuring the temperature, which is output via a separate current output. Inputs and outputs are galvanically isolated from each other.
Configuration
The transmitter is configured very easily using the LMA / MW22 software.
Technical data
| Measuring range: |
| ||||||
| Conductivity sensor: | All sensors of type 3L: LMN-1-3L with NTC for automatic temperature compensation | ||||||
| Conductivity output: | 0/4…20mA, load 200 ohm | ||||||
| Temperature output: | 0/4…20mA, load 200 ohm | ||||||
| Accuracy, linearity [% of full scale]: | ±2 ±1 after fine adjustment | ||||||
| Temperature measuring range, NTC [°C]: | 0…100 | ||||||
| Ambient temperature [°C]: | 0…60 | ||||||
| Operating voltage [V]: | 12V DC or 24V DC opt. (±10%, regulated) according to the type plate. A regulated supply voltage must be used. | ||||||
| Current consumption [mA]: | max. 50 |
Downloads
- Data sheet MW22
- Data sheet MW22-1000
- Configuration software MW22 and the SHA 256 signature for verification
- Software operating manual
Items & prices
| Art.-Nr. | Description | Net price | Order / enquire |
|---|---|---|---|
| 1-0022-8200 | MW22Output: 2x 4…20mA, supply voltage: 24V DCConductivity transmitter with galvanic isolationInput: conductivity sensor LMN-1-3L or LMN, temperature sensor NTCAdjustable measuring range: 10nS…200mS | €256.00 | |
| 1-0022-8210 | MW22-1000Output: 2x 4…20mA, supply voltage: 24V DCConductivity transmitter with galvanic isolationInput: conductivity sensor LMN-1-3L or LMN, temperature sensor NTCAdjustable measuring range: 10mS…1000mS | €256.00 |
All prices in euros net plus statutory VAT and shipping costs. Errors and changes excepted. Our terms and conditions apply: AGB.