Albert-Einstein-Straße 1, 49076 Osnabrück, Germany +49 541 959 88 44 0 info@imp24.de
imp ingenieurgesellschaft mbh Request list
Redox transmitter, 8 variants, (0)4…20mA or 0…5(10)V output

Transmitters

Redox transmitter

8 variants, (0)4…20mA or 0…5(10)V output

  • For connecting redox sensors, e.g. Au 110 and Pt 110
  • 8 variants:
    • 0…20mA, 4…20mA, 0…5V or 0…10V output
    • 12V or 24V DC operating voltage
  • Measuring range -1200mV…1200mV
  • Zero offset adjustment on the device
  • galvanic isolation
  • in a practical DIN-rail housing
  • Made in Germany

ab €198.00 net

Function

The device converts the high-impedance input signal of the redox sensor into a low-impedance output signal of 0(4)…20mA or 0…5/10V.

Input and output are galvanically isolated.

Advantages

Fully analogue:
The transmitters are equipped exclusively with analogue components. There is no falsification of the measurement results due to analogue/digital conversion.

Pin assignment
Pin assignment and zero point
Technical data
Redox measuring input: -1200mV…1200mV
Output: 0…20mA, 4…20mA, 0…5V or 0…10V
according to the type plate
Accuracy, linearity
[% of full scale]:
±1
Input resistance [ohm]: >1012
Operating voltage [V]: 12V DC or 24V DC opt. (±10%, regulated)
according to the type plate.
It is essential to use a regulated supply voltage.
Ambient temperature [°C]: 0…60
Degree of protection: IP 20
Current consumption [mA]: max. 70
Dimensions, H x W x D [mm]: 75 x 60 x 30
Weight [g]: 70

Items & prices

Art.-Nr.DescriptionNet priceOrder / enquire
1-0021-0510-1Output: 4 - 20mA, supply voltage: 24V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device€198.00
1-0021-0510-2Output: 0 - 20mA, supply voltage: 24V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device€198.00
1-0021-0510-3Output: 4 - 20mA, supply voltage: 12V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device€198.00
1-0021-0510-4Output: 0 - 20mA, supply voltage: 12V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device€198.00
1-0021-0510-5Output: 0 - 5V, supply voltage: 24V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device€198.00
1-0021-0510-6Output: 0 - 10V, supply voltage: 24V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device€198.00
1-0021-0510-7Output: 0 - 5V, supply voltage: 12V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device€198.00
1-0021-0510-8Output: 0 - 10V, supply voltage: 12V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device€198.00

All prices in euros net plus statutory VAT and shipping costs. Errors and changes excepted. Our terms and conditions apply: AGB.