Redox transmitter
8 variants, (0)4…20mA or 0…5(10)V output
- For connecting redox sensors, e.g. Au 110 and Pt 110
- 8 variants:
- 0…20mA, 4…20mA, 0…5V or 0…10V output
- 12V or 24V DC operating voltage
- Measuring range -1200mV…1200mV
- Zero offset adjustment on the device
- galvanic isolation
- in a practical DIN-rail housing
- Made in Germany
ab €198.00 net
Function
The device converts the high-impedance input signal of the redox sensor into a low-impedance output signal of 0(4)…20mA or 0…5/10V.
Input and output are galvanically isolated.
Advantages
Fully analogue:
The transmitters are equipped exclusively with analogue components. There is no falsification of the measurement results due to analogue/digital conversion.
Pin assignment
Technical data
| Redox measuring input: | -1200mV…1200mV |
| Output: | 0…20mA, 4…20mA, 0…5V or 0…10V according to the type plate |
| Accuracy, linearity [% of full scale]: | ±1 |
| Input resistance [ohm]: | >1012 |
| Operating voltage [V]: | 12V DC or 24V DC opt. (±10%, regulated) according to the type plate. It is essential to use a regulated supply voltage. |
| Ambient temperature [°C]: | 0…60 |
| Degree of protection: | IP 20 |
| Current consumption [mA]: | max. 70 |
| Dimensions, H x W x D [mm]: | 75 x 60 x 30 |
| Weight [g]: | 70 |
Items & prices
| Art.-Nr. | Description | Net price | Order / enquire |
|---|---|---|---|
| 1-0021-0510-1 | Output: 4 - 20mA, supply voltage: 24V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device | €198.00 | |
| 1-0021-0510-2 | Output: 0 - 20mA, supply voltage: 24V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device | €198.00 | |
| 1-0021-0510-3 | Output: 4 - 20mA, supply voltage: 12V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device | €198.00 | |
| 1-0021-0510-4 | Output: 0 - 20mA, supply voltage: 12V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device | €198.00 | |
| 1-0021-0510-5 | Output: 0 - 5V, supply voltage: 24V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device | €198.00 | |
| 1-0021-0510-6 | Output: 0 - 10V, supply voltage: 24V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device | €198.00 | |
| 1-0021-0510-7 | Output: 0 - 5V, supply voltage: 12V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device | €198.00 | |
| 1-0021-0510-8 | Output: 0 - 10V, supply voltage: 12V DCRedox transmitter with galvanic isolationMeasuring range: -1200…+1200mVZero offset adjustment on the device | €198.00 |
All prices in euros net plus statutory VAT and shipping costs. Errors and changes excepted. Our terms and conditions apply: AGB.