Albert-Einstein-Straße 1, 49076 Osnabrück, Germany +49 541 959 88 44 0 info@imp24.de
imp ingenieurgesellschaft mbh Request list

Conductivity sensors

Conductivity sensor LMA05

with current/voltage output, 4-electrode technology with Pt100

  • Conductivity sensor with 4-electrode technology
  • Measuring range programmable ex works
  • 0…200µS/…2000µS/
    …20mS/…200mS/…800mS/cm
  • with ISO measuring amplifier and output:
    • 0(4)…20mA
    • 0(2)…10V DC
  • Output is galvanically isolated
  • insensitive to contamination
  • for plastic union KV50 2-1/4" or immersion fitting TA32 possible
  • Made in Germany

ab €592.00 net

Advantages

Insensitive to contamination thanks to 4-electrode technology:
Contamination of the electrode with insulating substances (oils etc.) changes the cell constant and falsifies the measurement results.
With 4-electrode sensors, an additional currentless electric field measurement is carried out via sense measurement. The sensor is therefore less sensitive to contamination.

Integrated output electronics:
Output current or voltage is generated in the sensor. You save the cost of a transmitter or display unit; current or voltage can be fed directly into a PLC or similar. Even long cable runs can no longer falsify the measurement result.

Fully analogue:
The measuring amplifier is equipped exclusively with analogue components. There is no falsification of the measurement results due to analogue/digital conversion.

Programming ex works

The device is programmed to your requirements on delivery.

Please specify when ordering:

  • Measuring range
  • Temperature compensation
  • Analogue output.
Dimensions and pin assignment
green = current/voltage output
white = UB+
brown = UB ground
Technical data
Programmable measuring ranges: 0…200/ 2000µS/…20/…200/…800mS/cm
Measuring accuracy [%]: ±2 of full scale
Degree of protection: IP 65
Temperature compensation:
lin.: 0...3% / °C
nat. water: 2.2% / °C
Reference temperature: 25°C
Measuring surfaces: Electrographite / titanium / platinum
Cell shaft: PP, up to max. +50°C
Seal: O-ring Viton
Output: 0(4)…20mA DC / 0(2)…10V DC (with galvanic isolation)
Pressure resistance [bar]: 16
up to 60°C
Current consumption [mA]: max. 115
Fixed cable connection: 5m LIYY 3x0.34mm²
use shielded cable for lengths >5m.
Operating voltage [VDC]: 18…28
Current consumption [mA] max. 115
Installation: Immersion fitting TA32
KV50 2-1/4"

Items & prices

Art.-Nr.DescriptionNet priceOrder / enquire
1-0022-0307Conductivity sensor LMA05Active measuring cell with measuring amplifier4-electrode technology, insensitive to contaminationfor plastic union KV50 2-1/4" and/or immersion fitting TA32measuring range programmable ex works 0…200µS/…2000µS/…20mS/…200mS/…800mS/cmOutput 0/4…20mA, 0/2…10VDCMaterial: PP, Viton, titanium, electrographite, platinum€592.00

All prices in euros net plus statutory VAT and shipping costs. Errors and changes excepted. Our terms and conditions apply: AGB.