Albert-Einstein-Straße 1, 49076 Osnabrück, Germany +49 541 959 88 44 0 info@imp24.de
imp ingenieurgesellschaft mbh Request list
Ampere-hour meter AZ 2000

Ampere-hour meters

Ampere-hour meters

AZ 2000

  • Ah/Amin counter with 6-digit electromechanical totaliser
  • available as ampere-hour or ampere-minute counter
  • Connection to standard 60 mV shunt or equivalent signal outputs of electroplating rectifiers
  • Pulse output for controlling programmable diaphragm dosing pumps, e.g. Gamma /4 with Pulse Control
  • Made in Germany

ab €394.00 net

Function

The electromechanical totaliser can be reset with a key. For input voltages below 1 mV or above 150 mV, the LED range monitor signals that exact measurement is no longer possible (nominal voltage of a standard shunt = 60 mV). For currents up to 12 A, the shunt can be installed in the instrument.

Controls
Ampere-hour meter 1= electromech. totaliser
2= power indicator LED
3= measuring range indicator LED
Inputs/outputs
Input voltage [mV]: 60 (1-150)
For total current via potential isolation modules [V]: 10
Output pulses: Optocoupler: 10mA at Uce <0.7V; Uce max. 35V
optional relay output: 100V / 1A
Pulses: Totaliser to output: 1:1
Totaliser: electromechanical / 6-digit
(optional electronic LCD)
Accuracy [%]: 0.1
Special features: Suitable for connecting the Gamma /4 diaphragm dosing pump with Pulse Control for automatic dosing of bath additives
Adjustable measuring ranges
Ah counter [A]: ........300 A ,(2 decimal places)
......3000 A ,(1 decimal place)
...10 000 A ,(0 decimal places)
Amin counter [A]: ..........6 A ,(2 decimal places)
........60 A ,(1 decimal place)
......400 A ,(0 decimal places)
Asec counter / metal weight counter: on request
Special features: The calibration to the shunt data can also be changed subsequently by the customer.
Installation dimensions
Front panel [mm]: BxH 96x48
Required panel cut-out [mm]: BxH 90.5x43
Required installation depth [mm]: 180
Technical data
Operating voltage [V AC]: 230, -20% / +10%, 50/60 Hz
Power consumption [VA]: 3
Ambient temperature [°C]: 0…50
Housing: Panel-mount housing according to DIN 43700
Material: flame-retardant Noryl
Degree of protection: IP 44, according to EN 60529
Degree of protection with transparent door: IP 54
Weight [g]: 500
Climatic resistance: rel. humidity =< 75% without condensation
Electrical safety: according to EN 61 010
Clearances and creepage distances for
-overvoltage category II
-pollution degree 2
Protection class: 1
Electromagnetic compatibility: according to NAMUR recommendation NE21, EN 50 081 part 1, EN 50 082 part 2
Downloads

Items & prices

Art.-Nr.DescriptionNet priceOrder / enquire
1-2120-0000AZ 2000Ampere-hour metersTotaliserInput: 60mVShunt cable: 3mPlease state shunt data when ordering!€394.00

All prices in euros net plus statutory VAT and shipping costs. Errors and changes excepted. Our terms and conditions apply: AGB.