Albert-Einstein-Straße 1, 49076 Osnabrück, Germany +49 541 959 88 44 0 info@imp24.de
imp ingenieurgesellschaft mbh Request list

Highlights:

  • Ah/Amin counter with 6-digit electromechanical totaliser and electronic preset counter
  • with dosing electronics for time control of dosing valves or dosing pumps
  • Available as ampere-hour or ampere-minute counter
  • Connection to standard 60 mV shunt or equivalent signal outputs of electroplating rectifiers
  • Made in Germany
Function

The electromechanical totaliser can be reset with a key. For input voltages below 1 mV or above 150 mV, the LED range monitor signals that exact measurement is no longer possible (nominal voltage of a standard shunt = 60 mV). For currents up to 12 A, the shunt can be installed in the instrument.

Controls
Ampere-hour meter 1= electromech. totaliser
2= power indicator LED
3= measuring range indicator LED
4= pump control indicator LED
5= dosing time button
6= electronic LCD preset counter
Inputs/outputs
Input voltage [mV]: 60 (1-150)
For total current via potential isolation modules [V]: 10
Totaliser: electromechanical / 6-digit
(optional electronic LCD)
Preset counter: electronic LCD / 6-digit
electrically resettable
Accuracy [%]: 0.1
Preset counter output: Relay contact/potential-free 230V AC/0.5A or 30V DC/2A
for switching off the rectifier
DSZ dosing electronics: Setting range: 1…99s/100Ah
optional: 1…99s/10Ah
DSZ output relay: potential-free, 230V / 10A
Special features: Suitable for connecting any dosing device (solenoid valve, pump, ...) for automatic dosing of bath additives
Adjustable measuring ranges
Ah counter [A]: ........300 A ,(2 decimal places)
......3000 A ,(1 decimal place)
...10 000 A ,(0 decimal places)
Amin counter [A]: ..........6 A ,(2 decimal places)
........60 A ,(1 decimal place)
......400 A ,(0 decimal places)
Asec counter / metal weight counter: on request
Special features: The calibration to the shunt data can also be changed subsequently by the customer.
Installation dimensions
Front panel [mm]: BxH 144x72
Required panel cut-out [mm]: BxH 137x66
Required installation depth [mm]: 180
Technical data
Operating voltage [V AC]: 230, -20% / +10%, 50/60 Hz
Power consumption [VA]: 4
Ambient temperature [°C]: 0…50
Housing: Panel-mount housing according to DIN 43700
Material: flame-retardant Noryl
Degree of protection: IP 44, according to EN 60529
Degree of protection with transparent door: IP 54
Weight [g]: 1100
Climatic resistance: rel. humidity =< 75% without condensation
Electrical safety: according to EN 61 010
Clearances and creepage distances for
-overvoltage category II
-pollution degree 2
Protection class: 1
Electromagnetic compatibility: according to NAMUR recommendation NE21, EN 50 081 part 1, EN 50 082 part 2
Downloads

Items & prices

Art.-Nr.DescriptionNet priceOrder / enquire
1-2140-1400AZ 4000-DSZAmpere-hour metersTotaliser + preset counter + DSZ dosing electronicsInput: 60mVShunt cable: 3mPlease state shunt data when ordering!€1.108.00

All prices in euros net plus statutory VAT and shipping costs. Errors and changes excepted. Our terms and conditions apply: AGB.