Is the demineralisation unit mandatory?
The demineralisation unit is required if no DI water, i.e. demineralised water, is available (which is the case in most situations).
The water demineralisation unit is not included in the scope of delivery and must be ordered separately.
Depending on water hardness, we recommend a second demineralisation cartridge, which is then mounted in cascade with the 1st cartridge on the water inlet.
Which PCBs can be cleaned in the Öko 1000 / 2000?
The machine has various wash programmes, so that even sensitive components can be washed. There are practically no PCB components that cannot be cleaned in the machine.
Can third-party cleaners also be used?
As we do not know the composition of third-party cleaners, we unfortunately cannot give any warranty and therefore recommend our cleaners.
Do you help with the installation of the washing machines? Is there an introduction?
Within Germany, the Öko 1000 and 2000 are delivered by forwarding agent; on-site support during commissioning is not provided. However, we will gladly instruct your staff by telephone in the event of problems.
Which cleaner should I use?
For cleaning no-clean flux, we recommend component A+ in combination with Mix 3.
Mix 3 is sufficient for cleaning PCBs with rosin-based or water-soluble flux.
Can you give a dosing recommendation for A+ and Mix3?
The dosing quantity of component A+ should be 100-150 ml. This corresponds to 2-3% of the fill volume per wash step. We recommend a cleaning temperature of 60°C for component A+.
40-60 g of Mix3 should be dosed. Here the temperature should be set to 40°C. A higher temperature puts unnecessary stress on the items being washed.
Is Mix3 always required after component A+?
When cleaning with component A+, post-cleaning with Mix3 is required, as component A+ cannot completely wash off the flux. Component A+ acts as a "pathfinder" for Mix3.
Which connections must be available? 3/4" water inlet and outlet, possibly compressed air/vacuum,...? What must be considered during installation?
The following conditions are required for connecting the cleaning systems:
- Fresh water inlet:
- The external, pre-assembled solenoid valve is screwed directly onto a permanently installed water connection.
- Ideally use a water inlet with shut-off valve, 1/2" flow and a 3/4" male thread.
- The fill volume is approx. 5 litres for the Öko 2000 and 3.5 litres for the Öko 1000.
- The water pressure should be at least 2 bar, but no more than 8 bar.
- Waste water:
- The waste water hose (outer diameter: 28 mm) of the system leads via a downstream filter system, which is mounted on the wall below (Öko 1000) / above (Öko 2000) the machine installation level.
- After each programme step (cleaning/rinsing), the system pumps out the wash liquor/rinse water and then supplies fresh water again.
- After the filter, the hose must be routed into a vented drain that must end above (Öko 2000) or below (Öko 1000) the machine installation surface.
Local waste water regulations must be observed. See connection diagram in the manual. Neither compressed air nor vacuum is required for operation.
What must be considered regarding the power supply?
The Öko 1000 / 2000 must be operated at 220V-230V AC / 50Hz (single-phase). 60Hz is possible as a special version. AC power must be connected via a properly installed earthed socket. Fuse protection max. 16 amps.
What is the average detergent consumption? What are the operating costs?
For one wash process with 3% dosing, you need approx. 140 ml component A+ and 100 ml Mix 3. The cost of the cleaners is therefore approx. 4-5 euros per wash cycle.
For each cleaning / rinsing step, 4.5 - 5 litres of water are filled and then pumped out again. This results in a water consumption of approx. 27-30 litres for a complete wash cycle.
How much maintenance does the demineralisation unit require?
The demineralisation cartridge is monitored by a measuring unit during operation. If the conductivity at the outlet to the Öko rises, this is indicated visually by an LED directly on the measuring head and, if the limit value is exceeded, also on the display. Once the cartridge has reached saturation, it can be regenerated as often as required.
How much maintenance does the Öko 1000 / 2000 require?
Regular checks of the strainer inserts, the filter mat and the waste water filter are necessary. The surfaces of the optical sensors should be cleaned regularly. The seals on the door and the units may start to leak over time.
What ambient conditions does the system require (temperature, humidity, ...)?
The system is suitable for use indoors.
What do I need the activator for?
The optional activator is a defoamer that should be used if too much foam is produced during washing, leading to problems or error messages.
Which filters must be changed and how often?
The filter mat inside the machine and the filter cartridge in the waste water filter should be changed regularly. We recommend changing them approx. once a year or as required: the filter mat becomes porous and disintegrates over time, and the filter cartridge becomes clogged over time. Earlier replacement is advisable, e.g. if a lot of washing is done.
What is the detergent consumption?
Component A+: 2-3% of the filled water volume (approx. 150-180 ml), Mix3: 60-90 ml, activator: 20-40 ml. All values per wash cycle.
Are the cleaning racks only suitable for Euro cards?
Smaller PCBs can also be loaded. The three inner bars of the wash racks are adjustable down to a PCB side length of 3 cm. Alternatively, we offer our PCB holders Spike and Wave which can be used if the wash rack cannot be used, e.g. because components are located too far out on the PCB.
In your experience, what would be a gentle (and short) programme for cleaning flux residues from assembled FR4 PCBs in the Öko 2000?
The flux residues are, for example, run-offs around solder joints from hand soldering/repairs or white edges from the spray fluxer of the selective soldering system.
In general, you can try to reduce the cleaner dosage. The cleaning result will then show whether it is still sufficient or not.
Mix3 cannot be omitted. Component A+ is only required if "no-clean" fluxes are used. However, since white residues are mentioned, this is likely.
How often must the ion exchanger cartridge be regenerated?
This depends very much on the water hardness. The cartridge must be regenerated after 50 (very hard water) to 100 wash cycles (soft water). The machine monitors the conductivity of the water and indicates when the cartridge needs to be replaced.
The cartridges can be regenerated as often as required.